https://www.frascold.it
FVR-H-50-140
Title
Twin screw semi-hermetic compressor with built-in part-winding starting (PWS) electric motor and thermal protection probes connected to the electronic control module
Standard
•PWS (Y/YY) = 50Hz/380-420V/3Ph (60Hz/440-480V/3Ph)
•DOL (YY) = 50Hz/380-420V/3Ph (60Hz/440-480V/3Ph)
- Electric terminal box
- Control and protection electronic module INT69 FRY
- Discharge temperature sensor
- Suction shut-off valve
- Discharge flange with weld bushing
- Brazing connection for oil return piping
- Discharge check valve
- Safety valve
- Unloaded Start - Capacity control valves (only stems)
- ECO connection
- Rotalock valve with connection for oil return piping
- External oil circuit kit (control module, oil filter, flowswitch, solenoid valve, sight glass)
- Nitrogen charge (2bar min)
- Packaging for transport, handling and storage
Opzione
- Electric motors for various voltage supply values
- Capacity control valves with special voltage
- Special paint for off-shore installation
- Rubber dampers kit
- Valve connection kit for ECO
- Oil filter clogging differential pressure switch (Electronic)
- Electronic alarm control module for oil flow switch
- Discharge shut-off valves
SI IP
Rotors 2 # 2 #
Displacement @ 50 Hz 140 m3/h [50Hz] 4 CFH [50Hz]
Displacement @ 60 Hz 168 m3/h [60Hz] 5 CFH [60Hz]
Compressor version [1] 2 2
Nominal Motor power 38 kW 38 kW
Motor voltage at 50 Hz [2] 400 (+/-10%) V/3/50Hz PWS V/ph/Hz 400 (+/-10%) V/3/50Hz PWS V/ph/Hz
Motor voltage at 60 Hz [2] 460 (+/-10%) V/3/60Hz PWS V/ph/Hz 460 (+/-10%) V/3/60Hz PWS V/ph/Hz
PWS partition 50-50 50-50
Capacity control (CC) step 100-75 % 100-75 %
MRA, max operating current at 400V/50Hz and 460V/60Hz 89 A 89 A
LRA, max starting current at 400V/50Hz and 460V/60Hz, PWS motor 220 A 220 A
LRA, max starting current at 400V/50Hz and 460V/60Hz, PWS motor-DOL connection 340 A 340 A
Frequency min 30 Hz 30 Hz
Frequency max [3] 70 Hz 70 Hz
Control and protection device INT69 FRY INT69 FRY
Electric terminal box class protection IP65 IP65
Maximum pressure HP 30 bar 435.0 psi
Maximum pressure LP 20.5 bar 297.3 psi
Oil type [4] POE 170 cSt POE 170 cSt
Sight glass for oil circuit Standard Standard
Solenoid valve for oil circuit Standard Standard
Discharge check valve Standard Standard
Safety valve Standard Standard
Discharge temperature sensor Standard Standard
Suction valve (SV) mm 54 mm 54 mm
Suction valve (SV) inch 2" 1/8 inch 2" 1/8 inch
Net weight 223 kg 491.63 lb
Max Length 886 mm 34.91 inch
Max Width 495 mm 19.50 inch
Max Height 384 mm 15.13 inch
Compressor body material Cast Iron Cast Iron
Discharge bushing (DL) mm 42 mm 42 mm
Discharge bushing (DL) inch 1" 5/8 inch 1" 5/8 inch
Note
[1] Motor version: 1 = high and mid temp. all refrigerants; 2 = low and mid temp. all refrigerants; 3 = mid temp. R134a only
[2] Other motor voltage available on request
[3] Maximum frequency depends on the working conditions: use the FSS.3 (Frascold selection software)
[4] For alternative lubricants refer to bulletin FTEC022
List of available accessories
Accessory Accessory code
Special voltage for electric motor Contattare Frascold - Contact Frascold
Discharge Valve with soldering connections T00WK100650
Rubber dampers kit T00SK205200
Kit Connection for ECO or Liquid injection T00WK460
Electronic Alarm Control Module (for oil flow managment) T00EC28
Control and protection device INT69FRYL Diagnose T00EC45AD
Bridges for DOL start T00WK1203
Special painting Contattare Frascold - Contact Frascold
Oil filter clogging differential pressure switch T00WK151
Oil separator Selezionare il modello tramite software FSS3 - Select with FSS3
Air oil cooler Selezionare il modello tramite software FSS3 - Select with FSS3
Water oil coller Selezionare il modello tramite software FSS3 - Select with FSS3
Abbreviation Technical data SI IP
SV Suction valve (SV) 54mm - 2"1/8 54mm - 2"1/8
DL Discharge connection (DL) 42mm - 1"5/8 42mm - 1"5/8
1 Oil return connection (1) 22 mm 22 mm
2 Max. discharge temperature sensor - -
3 Low pressure connection (3) - -
4 High pressure connection (4) - -
5 Connection for ECO or Liquid injection - -
V1 Capacity control valve (Step 1) - -
NP Name Plate (NP) - -
Data sheets
Catalogues
Technical and product information bulletins
Use and maintenance instructions
Product brochure
Previous documentation (consultation only)
Installation and start up instructions
Conformity declarations and certifications
Technical and usage information
We'd love to hear from you

For application support or questions about our products, send us a message.Our experienced staff is one of our gratest assets, and they are ready to help. To find out why Blue Is Better, contact us today.